Protein quantification and immunoassay instruments - ELISA plate readers, lateral-flow readers, chemiluminescence imagers - share an architecture: an optical path, a detector, a motion system, a sample handler and a host that has to keep the whole run auditable. This note is about the host layer and how to choose it without overspending on compute the optics cannot use.
What the instrument requires
- Detector bandwidth. A photodiode or PMT with a 16 to 24 bit ADC is sampled on the MCU; the host receives integrated counts, not raw waveforms.
- Motion and positioning. Plate transport, filter wheels and shutter timing are MCU or FPGA tasks with encoder feedback.
- Imaging, where present. Chemiluminescence and gel documentation need a cooled sensor and long exposure; that is a camera subsystem, not a webcam.
- Assay protocol and audit trail. Every plate has to be traceable to a protocol version, a calibration curve, an operator and a timestamp, and exportable to LIMS.
Recommended configuration
| Function | Recommended TOPEET part |
|---|---|
| Instrument host: UI, protocol engine, LIMS link | iTOP-RK3568 Single Board Computer - 2x Gigabit Ethernet, RS-485 and CAN to the motion controller, SATA for run archives, LVDS panel |
| Compact reader with an imaging channel | iTOP-RK3562 Single Board Computer - 2x MIPI-CSI on the carrier, 1 TOPS NPU |
| Reader front panel or sample-prep module | iTOP-RK3506 Single Board Computer |
| Panel | 10.1-inch LVDS Display |
| Barcode and plate ID | OV5695 5 MP Camera Module for label reading at fixed distance |
Interface checklist
- Serial or CAN to the motion controller, with the host sending moves and receiving position, never closing the loop in Linux.
- Detector data over SPI or a dedicated ADC bus on the MCU side.
- Local archive on SATA or eMMC with a write-through design, plus daily export.
- Instrument-grade power: linear post-regulation on the analog rails, and the host on its own DC-DC.
- Service port and a documented calibration procedure in the manual.
What we would validate with you
Dark-count stability with the host under load, EMI from the display ribbon into the detector, and the run-log integrity test that a regulated lab will ask for.
Documents
English datasheets, schematics and BSP sources are in the resource portal. 12-month warranty, email engineering support.
Frequently asked questions
Does the host board sample the detector directly?
No. A photodiode or PMT with a 16 to 24 bit ADC is sampled on the MCU, and the host receives integrated counts rather than raw waveforms. That keeps the optical chain and the timing away from a general-purpose scheduler.
Which board for an ELISA or lateral-flow reader?
The iTOP-RK3568 as instrument host with dual Gigabit Ethernet, RS-485 and CAN to the motion controller, SATA for run archives and an LVDS panel; the iTOP-RK3562 for a compact reader with an imaging channel, two MIPI-CSI ports and a 1 TOPS NPU.
What does a regulated lab ask you to prove?
Dark-count stability with the host under load, EMI from the display ribbon into the detector, and run-log integrity across an interrupted run.